Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (HSYL-Q-720 (RTD-720B / 1380B)): B2B Engineering Overview
The Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B / 1380B) is an industrial-grade sterilization solution engineered for high-throughput hotels, central kitchens, and institutional catering across the Middle East (GCC) and Southeast Asia. Reinforced luxury double-door sterilizer with high-velocity circulating hot air that penetrates dense racks to dry tableware rapidly. Fabricated with AISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks, it delivers verified operational output (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C) under 220V–240V / 1Ph / 50–60Hz (380V on high-power models) supply and complies with IEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE.
125°C–150°C 3D Hot-Air Circulation Sterilization
- 125°C–150°C Far-Infrared / 3D Forced Hot-Air Circulation (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C): Achieves 2-Star hospital-grade thermal inactivation of E. coli, Staphylococcus aureus, and Hepatitis/Poliovirus across dense stacks of porcelain, glass, and stainless steel tableware.
- 45mm–50mm High-Density Thermal Insulation & Silicone Magnetic Gasket: Locks thermal energy inside the cavity so outer cabinet walls remain below 45°C even during peak 125°C–150°C sterilization cycles.
- Heavy-Load 6mm Solid SUS304 Wire Shelving / Custom Knife & Garment Racks: Supports 35–50 kg per shelf without sagging under heavy ceramic banquet plates or GN pans.
- Microcomputer LED Cycle Timer & Door-Open Safety Interlock: Automatically cuts UV-C, ozone, and heating elements the instant a door is opened during operation. Factory baseline configuration for HSYL-Q-720 (RTD-720B / 1380B): Type-Q Luxury Heavy-Duty Double-Door Sterilization Cabinet.
HACCP Pathogenic Inactivation & 6.75 kWh/Day Sterilization TCO
In humid Southeast Asian and GCC institutional kitchens, damp tableware stored on open shelves rapidly breeds mold and coliform bacteria. Running two 60-to-90-minute sanitization and drying cycles per day on the HSYL-Q-720 (RTD-720B / 1380B) consumes approximately 6.75 kWh/day, keeping sanitized tableware, knives, or cleanroom garments in a sealed, positive-pressure sterile environment for 24 hours. Long-life heating tubes (>8,000h) and plug-in digital PCBs ensure minimal maintenance cost. Configured specifically as a Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C), this unit integrates directly into standardized commercial sterilization lines with full factory spare-parts traceability.
Technical Specification Sheet & Sub-SKU Matrix
| Specification |
Value |
| IDENTITY |
| Model / Series Code | HSYL-Q-720 (RTD-720B / 1380B) |
| Equipment Designation | Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B / 1380B) |
| PERFORMANCE & ELECTRICAL |
| Core Engineering Specs | RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C |
| Power Supply / Energy Source | 220V–240V / 1Ph / 50–60Hz (380V on high-power models) |
| CONSTRUCTION & COMPLIANCE |
| Structural Material Grade | AISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks |
| Compliance & Design Standards | IEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE |
Sub-SKU Configuration Matrix (HSYL-Q-720):
| Model | Dimensions (mm) | Voltage | Rated Power | Net Volume | Temp Range | Sterilization Grade | Net Weight |
| Q-RTD-720 | 1310*650*1960 | 220V | 4.4 kW | 720 L | 50 ~ 125 ℃ | National 2-Star High-Temp Disinfection Standard | 118 kg |
Sub-SKU Configuration Matrix (RTD-720B / 1380B):
| Model | Dimensions (mm) | Rack Size | Voltage | Rated Power | Sterilization Temp | Tiers / Volume | Net Weight |
| RTP-336 | 650*650*1960 | 560*395*260 | 220V | 2.2 kW | 125 ℃ (50-125℃Adjustable) | 4-Tier / 336 L | 65 kg |
| RTD-720 | 1310*650*1960 | 560*395*260 | 220V | 4.4 kW | 125 ℃ (50-125℃Adjustable) | 8-Tier / 720 L | 115 kg |