2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet

Commercial dutyFactory configurationExport documentation

Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (HSYL-Q-720 (RTD-720B / 1380B)): B2B Engineering Overview

The Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B / 1380B) is an industrial-grade sterilization solution engineered for high-throughput hotels, central kitchens, and institutional catering across the Middle East (GCC) and Southeast Asia. Reinforced luxury double-door sterilizer with high-velocity circulating hot air that penetrates dense racks to dry tableware rapidly. Fabricated with AISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks, it delivers verified operational output (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C) under 220V–240V / 1Ph / 50–60Hz (380V on high-power models) supply and complies with IEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE.

125°C–150°C 3D Hot-Air Circulation Sterilization

  • 125°C–150°C Far-Infrared / 3D Forced Hot-Air Circulation (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C): Achieves 2-Star hospital-grade thermal inactivation of E. coli, Staphylococcus aureus, and Hepatitis/Poliovirus across dense stacks of porcelain, glass, and stainless steel tableware.
  • 45mm–50mm High-Density Thermal Insulation & Silicone Magnetic Gasket: Locks thermal energy inside the cavity so outer cabinet walls remain below 45°C even during peak 125°C–150°C sterilization cycles.
  • Heavy-Load 6mm Solid SUS304 Wire Shelving / Custom Knife & Garment Racks: Supports 35–50 kg per shelf without sagging under heavy ceramic banquet plates or GN pans.
  • Microcomputer LED Cycle Timer & Door-Open Safety Interlock: Automatically cuts UV-C, ozone, and heating elements the instant a door is opened during operation. Factory baseline configuration for HSYL-Q-720 (RTD-720B / 1380B): Type-Q Luxury Heavy-Duty Double-Door Sterilization Cabinet.

HACCP Pathogenic Inactivation & 6.75 kWh/Day Sterilization TCO

In humid Southeast Asian and GCC institutional kitchens, damp tableware stored on open shelves rapidly breeds mold and coliform bacteria. Running two 60-to-90-minute sanitization and drying cycles per day on the HSYL-Q-720 (RTD-720B / 1380B) consumes approximately 6.75 kWh/day, keeping sanitized tableware, knives, or cleanroom garments in a sealed, positive-pressure sterile environment for 24 hours. Long-life heating tubes (>8,000h) and plug-in digital PCBs ensure minimal maintenance cost. Configured specifically as a Type-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C), this unit integrates directly into standardized commercial sterilization lines with full factory spare-parts traceability.

Technical Specification Sheet & Sub-SKU Matrix

Specification Value
IDENTITY
Model / Series CodeHSYL-Q-720 (RTD-720B / 1380B)
Equipment DesignationType-Q Commercial 2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet (RTD-720B / 1380B)
PERFORMANCE & ELECTRICAL
Core Engineering SpecsRTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C
Power Supply / Energy Source220V–240V / 1Ph / 50–60Hz (380V on high-power models)
CONSTRUCTION & COMPLIANCE
Structural Material GradeAISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks
Compliance & Design StandardsIEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE
Sub-SKU Configuration Matrix (HSYL-Q-720):
ModelDimensions (mm)VoltageRated PowerNet VolumeTemp RangeSterilization GradeNet Weight
Q-RTD-7201310*650*1960220V4.4 kW720 L50 ~ 125 ℃National 2-Star High-Temp Disinfection Standard118 kg
Sub-SKU Configuration Matrix (RTD-720B / 1380B):
ModelDimensions (mm)Rack SizeVoltageRated PowerSterilization TempTiers / VolumeNet Weight
RTP-336650*650*1960560*395*260220V2.2 kW125 ℃ (50-125℃Adjustable)4-Tier / 336 L65 kg
RTD-7201310*650*1960560*395*260220V4.4 kW125 ℃ (50-125℃Adjustable)8-Tier / 720 L115 kg
FAQ

2-Door (720L) & 3-Door (1380L) Hot-Air Disinfection Cabinet Questions

What tableware or tool materials are compatible with the HSYL-Q-720 (RTD-720B / 1380B) sterilization temperature?

The HSYL-Q-720 (RTD-720B / 1380B) operates at 120°C–150°C high-temperature hot air (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C) and is designed for porcelain dishes, tempered glassware, and stainless steel GN pans/trays; do not load low-temp plastic or melamine into 125°C+ zones.

How is daily energy consumption (6.75 kWh/day) calculated for the HSYL-Q-720 (RTD-720B / 1380B)?

Each automated cycle heats to target temperature and holds for 45–60 minutes before entering insulated thermal retention, drawing roughly 3.38 kWh per cycle thanks to the 45mm–50mm foamed/rock-wool insulation barrier.

What installation and spare parts details should be confirmed before ordering the HSYL-Q-720 (RTD-720B / 1380B)?

Confirm unit dimensions (RTD-720B: 1200×550×1800mm (3.0kW) | RTD-1380B: 1800×550×1800mm (4.5kW) | ≤125°C) against your dishroom doorway width (or request Knock-Down panel delivery on XDF walk-in rooms), verify 220V/1Ph vs. 380V/3Ph power, and include spare heating tubes, UV lamps, and door gaskets.