Commercial Kitchen Equipment & Turnkey Project Engineering
Factory Product

Melamine Tableware Medium-Temp & UV Sterilization Cabinet

Commercial dutyFactory configurationExport documentation

Commercial Melamine Tableware Dedicated Medium-Temp & UV Sterilization Cabinet (HSYL-MA-A01/A02 & B01/B02): B2B Engineering Overview

The Commercial Melamine Tableware Dedicated Medium-Temp & UV Sterilization Cabinet (HSYL-MA Series) is an industrial-grade sterilization solution engineered for high-throughput hotels, central kitchens, and institutional catering across the Middle East (GCC) and Southeast Asia. Calibrated for melamine heat limits to prevent scorching or warping, combining dual UV/ozone sterilization with warm-air drying. Fabricated with AISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks, it delivers verified operational output (2-Door 720L (1200×600×1850mm, 2.4kW) | 3-Door 1380L (1800×600×1850mm, 3.6kW) | Thermostatic Control 75–85°C) under 220V–240V / 1Ph / 50–60Hz (380V on high-power models) supply and complies with IEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE.

75°C–85°C Melamine-Safe Medium-Temp & UV/Ozone Sterilization

  • Dedicated 75°C–85°C Medium-Temp PTC Drying + UV-C & Ozone (2-Door 720L (1200×600×1850mm, 2.4kW) | 3-Door 1380L (1800×600×1850mm, 3.6kW) | Thermostatic Control 75–85°C): Specifically calibrated below the 95°C thermal deformation threshold of A5 melamine resin tableware, preventing warping, blistering, or yellowing while achieving 99.99% bacterial kill.
  • 45mm–50mm High-Density Thermal Insulation & Silicone Magnetic Gasket: Locks thermal energy inside the cavity so outer cabinet walls remain below 45°C even during peak 125°C–150°C sterilization cycles.
  • Heavy-Load 6mm Solid SUS304 Wire Shelving / Custom Knife & Garment Racks: Supports 35–50 kg per shelf without sagging under heavy ceramic banquet plates or GN pans.
  • Microcomputer LED Cycle Timer & Door-Open Safety Interlock: Automatically cuts UV-C, ozone, and heating elements the instant a door is opened during operation. Factory baseline configuration for HSYL-MA-A01/A02 & B01/B02: Melamine Tableware Ozone & Medium-Temp Drying Sterilizer (Type A).

HACCP Pathogenic Inactivation & 5.40 kWh/Day Sterilization TCO

In humid Southeast Asian and GCC institutional kitchens, damp tableware stored on open shelves rapidly breeds mold and coliform bacteria. Running two 60-to-90-minute sanitization and drying cycles per day on the HSYL-MA-A01/A02 & B01/B02 consumes approximately 5.40 kWh/day, keeping sanitized tableware, knives, or cleanroom garments in a sealed, positive-pressure sterile environment for 24 hours. Long-life heating tubes (>8,000h) and plug-in digital PCBs ensure minimal maintenance cost. Configured specifically as a Commercial Melamine Tableware Dedicated Medium-Temp & UV Sterilization Cabinet (2-Door 720L (1200×600×1850mm, 2.4kW) | 3-Door 1380L (1800×600×1850mm, 3.6kW) | Thermostatic Control 75–85°C), this unit integrates directly into standardized commercial sterilization lines with full factory spare-parts traceability.

Technical Specification Sheet & Sub-SKU Matrix

Specification Value
IDENTITY
Model / Series CodeHSYL-MA-A01/A02 & B01/B02
Equipment DesignationCommercial Melamine Tableware Dedicated Medium-Temp & UV Sterilization Cabinet (HSYL-MA Series)
PERFORMANCE & ELECTRICAL
Core Engineering Specs2-Door 720L (1200×600×1850mm, 2.4kW) | 3-Door 1380L (1800×600×1850mm, 3.6kW) | Thermostatic Control 75–85°C
Power Supply / Energy Source220V–240V / 1Ph / 50–60Hz (380V on high-power models)
CONSTRUCTION & COMPLIANCE
Structural Material GradeAISI 304 / anti-fingerprint brushed stainless steel chamber, 45mm–50mm high-density polyurethane/rock-wool insulation & 6mm solid SUS304 racks
Compliance & Design StandardsIEC 60335-2-58 / GB 17988 (2-Star Escherichia coli & Poliovirus Inactivation), HACCP Sanitation Standard, CE
Sub-SKU Configuration Matrix (HSYL-MA-A01 / A02):
ModelDimensions (mm)Shelf Size (mm)VoltageRated PowerSterilization TempCompatible TablewareVolume / N.W.
RTP-336MA565*525*1960485*390*50220V1.1 kW60 ℃ (30-80℃Thermostatic)Melamine, Plastic, Glass, Wood & Bamboo370L / 49kg
RTP-720MA1155*525*1960525*390*50220V2.2 kW60 ℃ (30-80℃Thermostatic)Melamine, Plastic, Glass, Wood & Bamboo690L / 87kg
Sub-SKU Configuration Matrix (HSYL-MA-B01 / B02):
ModelDimensions (mm)Shelf Size (mm)VoltageRated PowerSterilization TempShelf TiersVolume / N.W.
RTP-336MB565*525*1960485*390*50220V1.1 kW60 ℃ (30-80℃Thermostatic)5 -TierMedium-Temp Drying Shelves370L / 76kg
RTP-720MB1155*525*1960525*390*50220V2.2 kW60 ℃ (30-80℃Thermostatic)10 -TierMedium-Temp Drying Shelves720L / 124kg
FAQ

Melamine Tableware Medium-Temp & UV Sterilization Cabinet Questions

What tableware or tool materials are compatible with the HSYL-MA-A01/A02 & B01/B02 sterilization temperature?

The HSYL-MA-A01/A02 & B01/B02 is engineered specifically for heat-sensitive melamine (A5 resin) bowls, fast-food trays, bamboo chopsticks, and polycarbonate cups (operating at 75°C-85°C + UV/Ozone), as well as ceramic and stainless steel ware.

How is daily energy consumption (5.40 kWh/day) calculated for the HSYL-MA-A01/A02 & B01/B02?

Each automated cycle heats to target temperature and holds for 45–60 minutes before entering insulated thermal retention, drawing roughly 2.70 kWh per cycle thanks to the 45mm–50mm foamed/rock-wool insulation barrier.

What installation and spare parts details should be confirmed before ordering the HSYL-MA-A01/A02 & B01/B02?

Confirm unit dimensions (2-Door 720L (1200×600×1850mm, 2.4kW) | 3-Door 1380L (1800×600×1850mm, 3.6kW) | Thermostatic Control 75–85°C) against your dishroom doorway width (or request Knock-Down panel delivery on XDF walk-in rooms), verify 220V/1Ph vs. 380V/3Ph power, and include spare heating tubes, UV lamps, and door gaskets.

Related Technical Guides

Planning & Selection Resources

Explore engineering sizing guidelines, capacity benchmarks and operational workflows for Melamine Tableware Medium-Temp & UV Sterilization Cabinet.

Project Enquiry

Plan Your Kitchen with an Engineering Team

Send your menu, meal volume, floor plan and utility conditions. We will identify the equipment logic, layout questions and technical data required before quotation.

Start Technical Discussion