High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-01/02/03 (RQ-12/24/36)): B2B Engineering Overview
The High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-12 / 24 / 36) is an industrial-grade intelligent steamer solution engineered for high-throughput hotels, central kitchens, and institutional catering across the Middle East (GCC) and Southeast Asia. Thickened stainless steel body with optimized blower-assisted combustion for smokeless operation, viewing window, and auto water fill. Fabricated with AISI 304 1.2mm pressurized inner steaming cavity, 50mm high-density polyurethane foam insulation & SUS304 rice/perforated trays, it delivers verified operational output (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)) under LPG (2800Pa) / Natural Gas (2000Pa) + 220V Digital Controller supply and complies with IEC 60335-2-42 / EN 203-1 (Commercial Steamers), NSF/ANSI 4, CE, SASO.
3D Saturated Steam Generation & Multi-Tray Chamber Design
- High-Efficiency SUS316L Steam Generator / Multi-Flue Finned Heat Exchanger (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)): Generates 100°C–105°C pressurized saturated steam within 3.5 minutes, cooking 50–250 kg of rice, dim sum, fish, or banquet meats in 35–40 minutes.
- 50mm Monoblock Polyurethane Insulation & Automotive EPDM Door Gasket: Locks thermal energy inside the cavity with zero steam leakage around the perimeter, keeping outer door temperatures below 48°C.
- Automatic Solenoid Water Fill, Floatless Level Probe & Dry-Burn Cutoff: Continuously monitors water reservoir depth and automatically cuts heating power with an audible alarm if water supply is interrupted.
- Independent Compartment / IoT / Precision Low-Temp Steaming Control: Supports precise timing and temperature curves (including 65°C–85°C delicate sea-cucumber rehydration on HS-01 or multi-door independent steaming on DC04). Factory baseline configuration for HSYL-RQ-01/02/03 (RQ-12/24/36): Standard Commercial Gas Steaming Cabinet.
Rapid 3-Minute Steam Generation & 92.4 kWh-Eq/Day Batch TCO
In high-volume canteen and catering operations, steaming cabinet insulation and heat-exchanger geometry dictate utility bills. The HSYL-RQ-01/02/03 (RQ-12/24/36) achieves 94%+ thermal transfer efficiency, reducing batch steaming energy consumption to approximately 92.4 kWh-equivalent per 6-hour production day—saving 32% compared to uninsulated legacy steamers. Weekly bottom-valve blowdown and descaling keep heating elements operating at peak efficiency for over 8 years. Configured specifically as a High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)), this unit integrates directly into standardized commercial intelligent steamer lines with full factory spare-parts traceability.
Technical Specification Sheet & Sub-SKU Matrix
| Specification | Value |
|---|
| IDENTITY |
| Model / Series Code | HSYL-RQ-01/02/03 (RQ-12/24/36) |
| Equipment Designation | High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-12 / 24 / 36) |
| PERFORMANCE & ELECTRICAL |
| Core Engineering Specs | RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW) |
| Power Supply / Energy Source | LPG (2800Pa) / Natural Gas (2000Pa) + 220V Digital Controller |
| CONSTRUCTION & COMPLIANCE |
| Structural Material Grade | AISI 304 1.2mm pressurized inner steaming cavity, 50mm high-density polyurethane foam insulation & SUS304 rice/perforated trays |
| Compliance & Design Standards | IEC 60335-2-42 / EN 203-1 (Commercial Steamers), NSF/ANSI 4, CE, SASO |
Sub-SKU Configuration Matrix (HSYL-BL-RQ08 / 10 / 12):
| Model | Tray Capacity | Dimensions (mm) | Ignition System | Exhaust Flue Dia. | Working Pressure | Net Weight |
|---|
| SZXT-08R | 8 TraysRotary Ignition | 720*640*1330 | Pull-Out / Rotary Ignition | Φ63 mm S/S Exhaust Flue | LPG2800Pa / NG 2000Pa | 63 kg |
| SZXT-10R | 10 TraysRotary Ignition | 720*640*1510 | Pull-Out / Rotary Ignition | Φ63 mm S/S Exhaust Flue | LPG2800Pa / NG 2000Pa | 76 kg |
| SZXT-12R | 12 TraysRotary Ignition | 720*640*1700 | Pull-Out / Rotary Ignition | Φ63 mm S/S Exhaust Flue | LPG2800Pa / NG 2000Pa | 89 kg |
| SZXT-24R | 24 TraysRotary Ignition | 1440*640*1700 | Dual Pull-Out Ignition Rails | Dual Φ63mm Independent Exhaust Flues | LPG2800Pa / NG 2000Pa | 150 kg |
Sub-SKU Configuration Matrix (HSYL-HH-DN08 / 10 / 12):
| Model | Tray Capacity | Dimensions (mm) | NG Consumption | LPG Consumption | Gas Pressure (Pa) | Net Weight |
|---|
| SZXT-06 (Gas ) | 6 TraysGas Model | 720*640*1150 | 1.1 m³/h | 0.65 kg/h | NG 2000 / LPG 2800 | 55 kg |
| SZXT-08 (Gas ) | 8 TraysGas Model | 720*640*1330 | 1.3 m³/h | 0.80 kg/h | NG 2000 / LPG 2800 | 62 kg |
| SZXT-10 (Gas ) | 10 TraysGas Model | 720*640*1510 | 1.5 m³/h | 0.95 kg/h | NG 2000 / LPG 2800 | 75 kg |
| SZXT-12 (Gas ) | 12 TraysGas Model | 720*640*1700 | 1.8 m³/h | 1.10 kg/h | NG 2000 / LPG 2800 | 88 kg |
| SZXT-24 (Gas ) | 24 TraysGas 2-Door | 1440*640*1700 | 3.6 m³/h | 2.20 kg/h | NG 2000 / LPG 2800 | 148 kg |
Sub-SKU Configuration Matrix (HSYL-RQ-JJ08 / 10 / 12):
| Model | Tray Capacity | Dimensions (mm) | Ignition Control | Gas Type | Control Panel | Net Weight |
|---|
| SZXT-08C | 8 TraysTouch-Control Gas | 720*640*1330 | Auto Pulse Ignition + Flameout Protection | NG 12T / LPG 20Y | LED Digital Touch Timer & Temp Control | 65 kg |
| SZXT-10C | 10 TraysTouch-Control Gas | 720*640*1510 | Auto Pulse Ignition + Flameout Protection | NG 12T / LPG 20Y | LED Digital Touch Timer & Temp Control | 78 kg |
| SZXT-12C | 12 TraysTouch-Control Gas | 720*640*1700 | Auto Pulse Ignition + Flameout Protection | NG 12T / LPG 20Y | LED Digital Touch Timer & Temp Control | 92 kg |
| SZXT-24C | 24 TraysTouch-Control Gas | 1440*640*1700 | Dual Independent Electronic Pulse Ignition | NG 12T / LPG 20Y | Dual Touch Panels for Zone Control | 155 kg |
Sub-SKU Configuration Matrix (HSYL-WZW-RQ08 / 10 / 12 / 24):
| Model | Tray Capacity | Dimensions (mm) | Panel Finish | Water Level Gauge | Gas Consumption | Net Weight |
|---|
| SZXT-08F | 8 TraysAnti-Fingerprint Brushed | 720*640*1330 | Imported Extra-Thick Anti-Fingerprint Stainless Steel | External Direct-Read Water Level Sight Glass | Energy-Saving Burner Cuts Gas Use by 30% | 65 kg |
| SZXT-10F | 10 TraysAnti-Fingerprint Brushed | 720*640*1510 | Imported Extra-Thick Anti-Fingerprint Stainless Steel | External Direct-Read Water Level Sight Glass | Energy-Saving Burner Cuts Gas Use by 30% | 78 kg |
| SZXT-12F | 12 TraysAnti-Fingerprint Brushed | 720*640*1700 | Imported Extra-Thick Anti-Fingerprint Stainless Steel | External Direct-Read Water Level Sight Glass | Energy-Saving Burner Cuts Gas Use by 30% | 91 kg |
| SZXT-24F | 24 TraysAnti-Fingerprint Brushed | 1440*640*1700 | Imported Extra-Thick Anti-Fingerprint Stainless Steel | Dual-Level Direct-Read Water Tank | Energy-Saving Burner Cuts Gas Use by 30% | 153 kg |
Sub-SKU Configuration Matrix (HSYL-RQ-DC03 / 04):
| Model | Tray Capacity | Dimensions (mm) | NG Consumption | Gas Inlet Pressure | Pan Size (mm) | Net Weight |
|---|
| SZXT16-2S (Solid Door) | 6 Trays (S/S Door) | 720*640*1500 | 1.1 m³/h | NG2000Pa / LPG2800Pa | 400*600*50 | 65 kg |
| SZXT16-2S (Glass Door) | 6 Trays (Tempered Glass Door) | 720*640*1500 | 1.1 m³/h | NG2000Pa / LPG2800Pa | 400*600*50 | 100 kg |
| SZXT16-3S (Solid Door) | 9 Trays (S/S Door) | 720*640*1850 | 1.1 m³/h | NG2000Pa / LPG2800Pa | 400*600*50 | 106 kg |
| SZXT16-3S (Glass Door) | 9 Trays (Tempered Glass Door) | 720*640*1850 | 1.1 m³/h | NG2000Pa / LPG2800Pa | 400*600*50 | 131 kg |