Commercial Kitchen Equipment & Turnkey Project Engineering
Factory Product

High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet

Commercial dutyFactory configurationExport documentation

High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-01/02/03 (RQ-12/24/36)): B2B Engineering Overview

The High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-12 / 24 / 36) is an industrial-grade intelligent steamer solution engineered for high-throughput hotels, central kitchens, and institutional catering across the Middle East (GCC) and Southeast Asia. Thickened stainless steel body with optimized blower-assisted combustion for smokeless operation, viewing window, and auto water fill. Fabricated with AISI 304 1.2mm pressurized inner steaming cavity, 50mm high-density polyurethane foam insulation & SUS304 rice/perforated trays, it delivers verified operational output (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)) under LPG (2800Pa) / Natural Gas (2000Pa) + 220V Digital Controller supply and complies with IEC 60335-2-42 / EN 203-1 (Commercial Steamers), NSF/ANSI 4, CE, SASO.

3D Saturated Steam Generation & Multi-Tray Chamber Design

  • High-Efficiency SUS316L Steam Generator / Multi-Flue Finned Heat Exchanger (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)): Generates 100°C–105°C pressurized saturated steam within 3.5 minutes, cooking 50–250 kg of rice, dim sum, fish, or banquet meats in 35–40 minutes.
  • 50mm Monoblock Polyurethane Insulation & Automotive EPDM Door Gasket: Locks thermal energy inside the cavity with zero steam leakage around the perimeter, keeping outer door temperatures below 48°C.
  • Automatic Solenoid Water Fill, Floatless Level Probe & Dry-Burn Cutoff: Continuously monitors water reservoir depth and automatically cuts heating power with an audible alarm if water supply is interrupted.
  • Independent Compartment / IoT / Precision Low-Temp Steaming Control: Supports precise timing and temperature curves (including 65°C–85°C delicate sea-cucumber rehydration on HS-01 or multi-door independent steaming on DC04). Factory baseline configuration for HSYL-RQ-01/02/03 (RQ-12/24/36): Standard Commercial Gas Steaming Cabinet.

Rapid 3-Minute Steam Generation & 92.4 kWh-Eq/Day Batch TCO

In high-volume canteen and catering operations, steaming cabinet insulation and heat-exchanger geometry dictate utility bills. The HSYL-RQ-01/02/03 (RQ-12/24/36) achieves 94%+ thermal transfer efficiency, reducing batch steaming energy consumption to approximately 92.4 kWh-equivalent per 6-hour production day—saving 32% compared to uninsulated legacy steamers. Weekly bottom-valve blowdown and descaling keep heating elements operating at peak efficiency for over 8 years. Configured specifically as a High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)), this unit integrates directly into standardized commercial intelligent steamer lines with full factory spare-parts traceability.

Technical Specification Sheet & Sub-SKU Matrix

SpecificationValue
IDENTITY
Model / Series CodeHSYL-RQ-01/02/03 (RQ-12/24/36)
Equipment DesignationHigh-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-12 / 24 / 36)
PERFORMANCE & ELECTRICAL
Core Engineering SpecsRQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)
Power Supply / Energy SourceLPG (2800Pa) / Natural Gas (2000Pa) + 220V Digital Controller
CONSTRUCTION & COMPLIANCE
Structural Material GradeAISI 304 1.2mm pressurized inner steaming cavity, 50mm high-density polyurethane foam insulation & SUS304 rice/perforated trays
Compliance & Design StandardsIEC 60335-2-42 / EN 203-1 (Commercial Steamers), NSF/ANSI 4, CE, SASO
Sub-SKU Configuration Matrix (HSYL-BL-RQ08 / 10 / 12):
ModelTray CapacityDimensions (mm)Ignition SystemExhaust Flue Dia.Working PressureNet Weight
SZXT-08R8 TraysRotary Ignition720*640*1330Pull-Out / Rotary IgnitionΦ63 mm S/S Exhaust FlueLPG2800Pa / NG 2000Pa63 kg
SZXT-10R10 TraysRotary Ignition720*640*1510Pull-Out / Rotary IgnitionΦ63 mm S/S Exhaust FlueLPG2800Pa / NG 2000Pa76 kg
SZXT-12R12 TraysRotary Ignition720*640*1700Pull-Out / Rotary IgnitionΦ63 mm S/S Exhaust FlueLPG2800Pa / NG 2000Pa89 kg
SZXT-24R24 TraysRotary Ignition1440*640*1700Dual Pull-Out Ignition RailsDual Φ63mm Independent Exhaust FluesLPG2800Pa / NG 2000Pa150 kg
Sub-SKU Configuration Matrix (HSYL-HH-DN08 / 10 / 12):
ModelTray CapacityDimensions (mm)NG ConsumptionLPG ConsumptionGas Pressure (Pa)Net Weight
SZXT-06 (Gas )6 TraysGas Model720*640*11501.1 m³/h0.65 kg/hNG 2000 / LPG 280055 kg
SZXT-08 (Gas )8 TraysGas Model720*640*13301.3 m³/h0.80 kg/hNG 2000 / LPG 280062 kg
SZXT-10 (Gas )10 TraysGas Model720*640*15101.5 m³/h0.95 kg/hNG 2000 / LPG 280075 kg
SZXT-12 (Gas )12 TraysGas Model720*640*17001.8 m³/h1.10 kg/hNG 2000 / LPG 280088 kg
SZXT-24 (Gas )24 TraysGas 2-Door1440*640*17003.6 m³/h2.20 kg/hNG 2000 / LPG 2800148 kg
Sub-SKU Configuration Matrix (HSYL-RQ-JJ08 / 10 / 12):
ModelTray CapacityDimensions (mm)Ignition ControlGas TypeControl PanelNet Weight
SZXT-08C8 TraysTouch-Control Gas720*640*1330Auto Pulse Ignition + Flameout ProtectionNG 12T / LPG 20YLED Digital Touch Timer & Temp Control65 kg
SZXT-10C10 TraysTouch-Control Gas720*640*1510Auto Pulse Ignition + Flameout ProtectionNG 12T / LPG 20YLED Digital Touch Timer & Temp Control78 kg
SZXT-12C12 TraysTouch-Control Gas720*640*1700Auto Pulse Ignition + Flameout ProtectionNG 12T / LPG 20YLED Digital Touch Timer & Temp Control92 kg
SZXT-24C24 TraysTouch-Control Gas1440*640*1700Dual Independent Electronic Pulse IgnitionNG 12T / LPG 20YDual Touch Panels for Zone Control155 kg
Sub-SKU Configuration Matrix (HSYL-WZW-RQ08 / 10 / 12 / 24):
ModelTray CapacityDimensions (mm)Panel FinishWater Level GaugeGas ConsumptionNet Weight
SZXT-08F8 TraysAnti-Fingerprint Brushed720*640*1330Imported Extra-Thick Anti-Fingerprint Stainless SteelExternal Direct-Read Water Level Sight GlassEnergy-Saving Burner Cuts Gas Use by 30%65 kg
SZXT-10F10 TraysAnti-Fingerprint Brushed720*640*1510Imported Extra-Thick Anti-Fingerprint Stainless SteelExternal Direct-Read Water Level Sight GlassEnergy-Saving Burner Cuts Gas Use by 30%78 kg
SZXT-12F12 TraysAnti-Fingerprint Brushed720*640*1700Imported Extra-Thick Anti-Fingerprint Stainless SteelExternal Direct-Read Water Level Sight GlassEnergy-Saving Burner Cuts Gas Use by 30%91 kg
SZXT-24F24 TraysAnti-Fingerprint Brushed1440*640*1700Imported Extra-Thick Anti-Fingerprint Stainless SteelDual-Level Direct-Read Water TankEnergy-Saving Burner Cuts Gas Use by 30%153 kg
Sub-SKU Configuration Matrix (HSYL-RQ-DC03 / 04):
ModelTray CapacityDimensions (mm)NG ConsumptionGas Inlet PressurePan Size (mm)Net Weight
SZXT16-2S (Solid Door)6 Trays (S/S Door)720*640*15001.1 m³/hNG2000Pa / LPG2800Pa400*600*5065 kg
SZXT16-2S (Glass Door)6 Trays (Tempered Glass Door)720*640*15001.1 m³/hNG2000Pa / LPG2800Pa400*600*50100 kg
SZXT16-3S (Solid Door)9 Trays (S/S Door)720*640*18501.1 m³/hNG2000Pa / LPG2800Pa400*600*50106 kg
SZXT16-3S (Glass Door)9 Trays (Tempered Glass Door)720*640*18501.1 m³/hNG2000Pa / LPG2800Pa400*600*50131 kg
FAQ

High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet Questions

What is the main selection task for High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet (HSYL-RQ-01/02/03 (RQ-12/24/36))?

Dense grains, root vegetables, and delicate seafood have different steam penetration needs. Check the actual 400×600mm or GN 1/1 solid/perforated tray dimensions, vertical rail spacing, and loaded food height (RQ-12: 800×850×1750 (28kW) | RQ-24: 1500×850×1750 (52kW) | RQ-36: 2150×850×1750 (78kW)); nominal tray count alone does not establish usable batch output.

How should operating and descaling maintenance costs be compared for HSYL-RQ-01/02/03 (RQ-12/24/36)?

Compare measured electricity or gas consumption per 50 kg rice/food batch (92.4 kWh-eq/day average) together with local water hardness treatment and weekly drain-valve descaling labor to prevent heating-tube calcification.

Which supply and after-sales terms should be confirmed before ordering HSYL-RQ-01/02/03 (RQ-12/24/36)?

Request a written quote specifying HSYL-RQ-01/02/03 (RQ-12/24/36), quantity of solid vs. perforated SUS304 trays (and roll-in trolleys if applicable), spare SUS316L heating tubes or gas igniters, silicone door gaskets, packed crate CBM, and destination utility voltage/gas pressure.

Related Technical Guides

Planning & Selection Resources

Explore engineering sizing guidelines, capacity benchmarks and operational workflows for High-Efficiency Energy-Saving Commercial Gas Steaming Cabinet.

Project Enquiry

Plan Your Kitchen with an Engineering Team

Send your menu, meal volume, floor plan and utility conditions. We will identify the equipment logic, layout questions and technical data required before quotation.

Start Technical Discussion