Direct Answer / Key Takeaway: Agree floor levels, the selected channel edge, membrane connection and outlet before construction. Assign inspection points before the assembly is concealed.
A floor trough is installed within a floor assembly. The channel edge, grate support, waterproofing, topping and downstream connection must work together. Ordering a stainless channel before those interfaces are agreed can leave the site team trying to solve a concealed detail during construction.
Set the levels from the finished floor
Show the intended finished surface, grate position, channel body and outlet on a section. Identify the actual floor layers and any restrictions in the supporting structure. Use the surveyed downstream connection level rather than assuming a generic shallow channel will fit.
Coordinate the surrounding falls with the catchment design and usable floor routes. The project's responsible designers should define the required geometry. Do not copy a civil driveway detail or a shower-channel offset into a commercial kitchen simply because both products are called channel drains.
Resolve the edge and waterproofing interface
Identify the exact channel-edge construction being supplied. Where waterproofing is part of the floor design, have the channel supplier, membrane specialist and floor contractor agree the compatible connection detail. A flange shown in a brochure is not proof that the selected unit contains that flange or that every membrane bonds to it in the same way.
Clarify the treatment at corners, ends and any channel joints. Record which party supplies and completes each interface. Manufacturer ACO's installation resources distinguish product instructions from the wider conditions in which drainage is installed; the same coordination principle applies without transferring its material or dimensional details to another product.
| Before concealment | Responsibility to agree |
|---|---|
| Support and position | Who sets and checks the supplied assembly against the level drawing |
| Drain connection | Who verifies the actual route and approved joint |
| Membrane interface | Who approves compatibility and inspects the completed detail |
| Floor finish | Who confirms surrounding levels and usable transitions |
Protect the assembly through construction
Use the selected manufacturer's instructions for support, temporary protection and any required measures during surrounding construction. Keep debris out of the approved drainage path. Do not substitute a generic pour sequence or remove supporting components where the instructions require them to remain.
Agree inspection and testing methods with the responsible project team before work is covered. Record results and any defects at the stage where they can still be assessed. A final photograph of a fitted grate cannot demonstrate the concealed membrane connection.
At completion, check that the supplied grate fits its intended support and remains removable by the approved method. Confirm collection and cleaning access after adjacent equipment is installed. Store the final detail and acceptance records with the project's installation documents so future floor repairs can preserve the actual assembly. The fabrication interface review guide can support that coordination; it does not describe the concealed detail at this site.