Undercounter Commercial Fridge
Compare undercounter commercial fridges by installation space, door clearance, container fit and food temperature. Review E Series cabinet references.
An undercounter commercial fridge can match the width of an opening and still be unsuitable for it. The missing checks are often installed height, heat rejection, door movement and access to components that need cleaning or service. Measure the workstation before choosing the largest cabinet that appears to fit.
Measure the opening in its working condition
Measure clear width at the front and back, height at both sides, and usable depth after accounting for wall finishes, pipes and sockets. Record any floor slope, countertop support and front overhang. A nominal kitchen drawing may not show these obstructions.
Next, mark the area the door and handle occupy when opened. Check that staff can remove the intended containers without blocking the adjacent workstation. Include the route from the delivery entrance; an appliance that fits beneath the counter may not pass a narrow turn on its way there.

Compare depth before committing to storage volume
These published E Series air-cooling refrigerator examples have the same listed width and height. Their depth and capacity differ:
| Model | Published dimensions | Published capacity |
|---|---|---|
| ECUR12-2 600 | 1200 × 600 × 800 mm | 160 L |
| ECUR12-2 700 | 1200 × 700 × 800 mm | 200 L |
| ECUR12-2 800 | 1200 × 800 × 800 mm | 240 L |
The E Series model table lists 2–8°C for these refrigerator configurations. Confirm the required product storage conditions, operating ambient and loaded performance for your application. The figures above are cabinet dimensions, not the minimum opening sizes after ventilation and connection allowances.
Do not buy the 800 mm-deep version solely for its larger litre figure if it reduces aisle space or cannot ventilate in the proposed position. Conversely, a shallow cabinet may require more frequent replenishment. Draw the actual container layout to compare that trade-off.
Get four answers from the installation drawing
- Where does cooling air enter and leave? Keep the specified paths clear. A freestanding workbench is not automatically approved for enclosed installation.
- What is the complete installed height? Confirm feet or castors, any adjustment range and the supplied top. Do not remove a top or change supports without approval.
- How are services connected? Locate the electrical connection and any drainage requirement for the offered version. Keep connections accessible as instructed.
- How is it serviced? Establish which panel opens and whether the cabinet must pull forward. Plan a practical way to do that after the rest of the kitchen is installed.
If the supplier cannot confirm an enclosed installation, consider retaining a freestanding refrigerated workbench in a suitable position instead of forcing it into the recess.
Test storage with the containers you use
List the pan, box and bottle dimensions, including lids. Ask for usable shelf dimensions, adjustment positions and loading limits. Keep the manufacturer's airflow paths clear when mapping the layout. Nominal litres do not show whether a tall ingredient container fits behind the door or whether a second row remains accessible during service.
For a prep station, record how many containers must be ready at the start of the busy period and how often staff can replenish them. This produces a more useful cabinet requirement than the total amount held elsewhere in the kitchen.
Compare a different cabinet family only after checking duty
The A2R/A2F undercounter cabinet page provides another family to discuss. Similar-looking cabinets do not establish identical chilled or frozen duty. Request the exact operating temperature, installed dimensions and ventilation requirements before treating one as a replacement for an E Series unit.
Send a dimensioned opening sketch and your container list to HSYL, together with photographs of surrounding equipment and the available supply. Ask for a drawing-based fit check for the exact model quoted.
Related Kitchen Products
Selected from the catalogue against the keywords of this page, then reviewed with your duty cycle, utilities and site conditions before quotation.

XSDUF-SALAD S Series Static Cooling Salad Table Fridge
S Series static-cooling salad prep table fridge, e.g. XSDUR18-2S 800: 480 L, 1800 x 800 x 1050 mm, 2–8C, R290. Plan pans, refills and chilled storage.
View product
ECUR-EDTR Fan Cooling E Series Salad Table Fridge
ECUR E Series fan-cooled salad prep fridge, e.g. ECUR18-2S 800: 445 L, 1800 x 800 x 1050 mm, 2–8C, R290. Confirm the pan layout of the exact configuration.
View product
Combi Oven (HSYL-CK-CO01)
HSYL-CK-CO01 compact combi oven: steam 1.7 kW / convection 2 kW at 220V-50Hz, 8-inch touchscreen, 200 programs of up to 15 steps, 598 x 610 x 478 mm, 35 kg.
View productEngineering-Led Commercial Kitchen Manufacturing
HSYL Kitchen Systems designs and produces heavy-duty commercial kitchen equipment for central kitchens, hotels, canteens, hospitals and high-capacity restaurants. Our goal is to provide precise equipment matching, documented quality gates and verified delivery for global foodservice operations.
- Food-grade SUS304 & SUS316 stainless steel construction
- Custom engineering layout & CAD drawing support
- Multi-stage factory quality control & FAT testing
- Factory-direct supply chain with spare parts backup

Advanced OEM Processing Equipment & Lines
Equipped with world-class automated sheet metal processing, precision bending centers, thermal foaming lines, and vacuum test rigs to support high-volume commercial kitchen OEM/ODM manufacturing.
Italian Salvagnini Panel Bending Center
Automated sheet metal bending system for seamless cabinet fabrication and tight structural tolerances.
Automated Bending & Laser Cutting Line
Integrated flexible processing line combining fiber laser cutting and multi-axis CNC bending.
Constant-Temperature Foaming Line
Continuous polyurethane thermal insulation foaming line ensuring uniform core density.
Vacuum Extraction & Testing Line
High-vacuum circuit evacuation and automated leak detection for commercial cooling systems.
Laser Cutting & CNC Punching Station
High-speed fiber laser cutting and precision CNC punching for intricate component fabrication.
Canadian Heavy-Duty CNC Press Brake
High-tonnage precision press brake for large-format stainless steel sheet forming.
Material Shearing & Cutting Line
Automated heavy-gauge stainless steel shearing and precision raw material sizing.
Material Film Laminating Line
Automated surface protection film application to preserve satin and mirror metal finishes.
Explore Popular Kitchen Equipment
Browse equipment that visitors frequently explore, then review the exact model and specifications for your project.
Stainless Steel Wall Shelves
Stainless steel wall shelves sized from stored load, shelf depth and wall substrate, leavi...
View product
E Series Display Refrigerator Range
E Series display refrigerators in direct and air cooling, e.g. EDTR24-1G single door, 380 ...
View product
Commercial Meat Slicer-FP-HB-350400
HB-350 and HB-400 commercial meat slicers: 363 mm or 385 mm blades, 0.2–20 mm slices, 380V...
View product
HDW8000L Steam-Heated Commercial Dishwasher
HDW8000L steam-heated commercial dishwasher, catalogue rating 8000 plates/hour, for contin...
View product
Two-Compartment Commercial Sinks
Two compartment commercial sinks: define each bowl's job, measure internal bowls and ...
View product
E234-BCW02-11 Horizontal Banquet Cart
E234-BCW02-11 horizontal heated banquet cart: 234 L, 4 layers, 10–80C, 2.2 kW at 220 V, 10...
View product
700-Series Combined Western Kitchen Stove
700-Series combined western kitchen stove, CK-BERTO, in AISI 304 for electric 380V/3P, LPG...
View product
Commercial Meat Mixers
Choose a commercial meat mixer by recipe, meat temperature, inclusion ratio and mixing tim...
View product
Commercial Ovens for Professional Kitchens
Commercial ovens for professional kitchens chosen by tray format, cooking process, batch r...
View product
Stainless Steel Kitchen Trolleys
Stainless steel kitchen trolleys configured for payload, GN pan or tray format, travel rou...
View product
HP Countertop Gas Pasta Cooker Range
HP countertop gas pasta cookers: HP6035G (350 mm, 5.5 kW) and HP6060G (600 mm, 11.0 kW). M...
View productQ and S Series Direct-Cooling Display Cabinet Range
Q and S Series direct-cooling display cabinets, e.g. QDTR24-1G single door, 370 L, 2–8C, R...
View product
Commercial Steak & Beef Dry-Aging Cabinet with Himalayan Salt Brick & UV Sterilization
HSYL-SN-01 steak and beef dry-aging cabinet with Himalayan salt brick, UV sterilization an...
View product
HDW260-EL-R Electric-Heated Commercial Dishwasher
HDW260-EL-R electric-heated rack dishwasher: 260 racks/hour, 500 x 500 mm racks, 2632 x 81...
View product
Commercial Induction Stockpot Soup Stove
1, 2 or 3-burner induction stockpot soup stove with 400400mm tempered glass top. Zero idle...
View product
Frost-Free 3D Fan-Cooled 2/4/6-Door Upright Commercial Chiller & Freezer
Frost-free fan-cooled upright commercial chiller and freezer in 2, 4 and 6-door sizes (380...
View product
Commercial Stainless Steel Roast Duck & Cantonese Char Siu Air-Drying Chiller Cabinet
HSYL-ZS-LY stainless air-drying chiller cabinet for roast duck and char siu: 5–15C with 50...
View product
Multi-Door Independent Compartment Commercial Electric Steamer
Multi-door commercial electric steamer with independent per-compartment temperature contro...
View productFrequently Asked Questions
Can an 800 mm-high cabinet fit in an 800 mm-high opening?
A matching nominal height is not sufficient. Check the complete installed height, levelling or support arrangement, countertop obstructions and the installation allowances required for that model.
Can I place hot cooking equipment on the refrigerated worktop?
Do not assume the top is approved for that load or heat exposure. Provide the appliance weight, feet position and heat output, and request written compatibility guidance for the proposed arrangement.
Does the listed cabinet capacity equal usable container space?
No. Shelves, internal components, the container shape and required airflow affect the working layout. Compare the actual container arrangement rather than converting the litre figure directly into portions.
Plan the Equipment Around Your Kitchen.
Share your menu, peak service demand, available space and site utilities. Tell us which equipment you are considering so we can review the requirements with you.